A 20 μl aliquot of this phage stock was added to 180 μl of rat blood (i.e. a 1 in 10 dilution) and 20 μl of this dilution was added to another 180 μl of rat blood. This serial dilution was continued to an expected 3 PFU/ml concentration. Plaque assays were carried out in triplicate and the average PFU/ml ± S.D. was plotted via the concentration calculated from phage stock. This curve was used to correlate
the actual phage stock concentration to concentrations detected from blood samples. Linear regression analysis was used to construct the equation of the line. The correlation coefficient (R2) was also calculated to assess the linearity of the data. Where appropriate, statistical analyses of the results were performed with a one-way analysis of variance, and a two-way analysis of variance (ANOVA). In all cases p < 0.05 was taken to represent a statistically check details significant difference. The software package used was GraphPad Prism 5 (GraphPad software Inc., San Diego, California, USA). The images of the PC MN arrays are presented in Fig. 3. The mean height and base diameter for the PC MNs were approximately 995 μm and 750 μm, respectively. The hollow bore diameter was ≈100 μm. The aspect ratio was 1.3. The X-ray tomography images illustrate both the MN array and also the structure of the reservoirs at the base of each MN. The He-ion technology
produced ultra sharp images of the PC needles. The rich surface specific information is due to the unique nature of the beam- sample interaction. From the this website insertion forces studies of the PC arrays prior to fabrication of the MN device, it was observed that, at all Rolziracetam three forces investigated (i.e. 0.05, 0.1 and 0.4 N/needle), MNs penetrated the SC of the skin. Therefore, 100% penetration efficiency was observed, regardless of the applied force.
Light microscope analysis showed that no decrease in MN height was observed upon removal from skin, regardless of the force of application. Fracture force studies carried out on the MNs can be observed in Fig. 4a. At forces of 0.05 N/needle, there was no significant change in MN height. However, when the axial force was increased, the% reduction in height increased. Fig. 4b shows the morphology of MNs following 0.4 N/needle force application, with apparent damage at the tip of the needles. The 2D OCT image of the MNs following insertion into neonatal porcine skin is illustrated in Fig. 5. It was found that the MNs penetrated to an approximate depth of 700 μm and created a pore of approximate width 600 μm whilst the MNs were in situ. Fig. 5 also shows a 3D image of MNs in situ following insertion into neonatal porcine skin. It was found that, immediately following the removal of MNs from the neonatal porcine skin, the residual skin pore had a depth of approximately 210 μm, and a width of approximately 600 μm but quickly closed over (1 h, data not shown).